Water
Cold and hot water pipes and the tap points they run to.
Pick Cold pipe, Hot pipe or Tap point in the Water section of the library, or press A and choose in the context bar.
Tap points
A tap point marks where a fitting connects. Choose a preset in the context bar and tap where it goes.
| Preset | Supply | Connection height |
|---|---|---|
| Washbasin | cold and hot | 55 cm |
| WC | cold | 15 cm |
| Shower | cold and hot | 110 cm |
| Washing machine | cold | 100 cm |
| Kitchen sink | cold and hot | 50 cm |
| Outside tap | cold | 60 cm |
Supply, label and height can be changed in the inspector. The label and height are written next to the point on the plan.
A tap point can also be made from a pipe: select a point of a water pipe and mark it as a tap point. The fitting then sits exactly on the pipe.
Pipes
Tap the points of the route. A pipe snaps to tap points, corners, walls and guides. Finish with Return, Esc, Finish, or by tapping the last point again.
Cold pipes are drawn blue, hot pipes red.
A pipe that ends exactly on a tap point is connected to it: move the tap point and the pipe end goes with it.
Editing a route works as for cables: drag points, drag a segment’s middle to add a point, delete a selected point, or extend from an end. Shift-click selects several points, which then move together with the arrow keys.
Lengths
The inspector shows the length of the selected pipe. The material list adds up cold and hot pipe separately, as drawn and with a 10 % allowance, and lists the tap points.
Lengths are measured on the plan. Vertical runs, from the floor up to the connection height, are not included; add them when you order.
The layer
Pipes and tap points are on the Water layer.